Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP21
Width
107mm
Depth
150mm
Height
143mm
Supporting protocol for SERCOS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for Modbus
Yes
Supporting protocol for LON
Yes
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for DeviceNet
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFINET IO
No
Supporting protocol for ASI
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIBUS
No
Supporting protocol for PROFIsafe
No
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Supporting protocol for KNX
No
Number of interfaces PROFINET
0
Number of HW-interfaces other
0
Supporting protocol for TCP/IP
No
Supporting protocol for CAN
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of digital inputs
3
Number of digital outputs
0
With optical interface
No
With control element
Yes
Number of analogue outputs
1
4-quadrant operation possible
No
Integrated breaking resistance
No
Nominal output current I2N
4.6A
With PC connection
Yes
Application in domestic- and commercial area permitted
Yes
Max. output frequency
200Hz
Max. output at linear load at rated output voltage
0.75kW
Max. output voltage
240V
Mains voltage
200 - 240V
Type of converter
U converter
Application in industrial area permitted
Yes
Max. output at quadratic load at rated output voltage
0.75kW
Number of phases output
3
Relative symmetric net frequency tolerance
5%
Relative symmetric net voltage tolerance
10%
Number of phases input
3
Supporting protocol for BACnet
No
Mains frequency
50/60 Hz
Number of analogue inputs
2
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV212H075M3X
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP21
Width
107mm
Depth
150mm
Height
143mm
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Supporting protocol for Modbus
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for DeviceNet Safety
Supporting protocol for DeviceNet
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFINET IO
Supporting protocol for ASI
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIBUS
Supporting protocol for PROFIsafe
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Supporting protocol for KNX
Number of interfaces PROFINET
0
Number of HW-interfaces other
0
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for other bus systems
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of digital inputs
3
Number of digital outputs
0
With optical interface
With control element
Number of analogue outputs
1
4-quadrant operation possible
Integrated breaking resistance
Nominal output current I2N
4.6A
With PC connection
Application in domestic- and commercial area permitted
Max. output frequency
200Hz
Max. output at linear load at rated output voltage
0.75kW
Max. output voltage
240V
Mains voltage
200 .. 240V
Type of converter
U converter
Application in industrial area permitted
Max. output at quadratic load at rated output voltage
0.75kW
Number of phases output
3
Relative symmetric net frequency tolerance
5%
Relative symmetric net voltage tolerance
10%
Number of phases input
3
Supporting protocol for BACnet
Mains frequency
50/60 Hz
Number of analogue inputs
2
From same serie
We use cookies to enhance your experience.