Aleta.hr
Main Product Image

A9N21560

Code: 1694789

ManufacturerSchneider
Catalog numberA9N17515
EAN code3606480382437
Order only
Zagreb0 pcs
Zadar0 pcs

Sign in or create an account for lower prices and other benefits


WSP*
14,80 €
Neto14,80
RP18,50
pcs

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

No

Rated current

32A

Built-in depth

70mm

Width in number of modular spacings

1

Rated voltage

230V

Release characteristic

C

Number of protected poles

1

Number of poles (total)

2

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Additional equipment possible

Yes

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Pollution degree

3

Over voltage category

3

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

A9N21560

Main Product Image

Code

1694789

Catalog number

A9N17515

Type

Miniature circuit breaker (MCB)

Manufacturer

Schneider

Serie

-

Neto WSP:

14,80

RP:18,50
* Minimum quantity1

Total stock:

0 PCS

Zadar0 PCS
Zagreb0 PCS

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC

Suitable for flush-mounted installation

Rated current

32A

Built-in depth

70mm

Width in number of modular spacings

1

Rated voltage

230V

Release characteristic

C

Number of protected poles

1

Number of poles (total)

2

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Additional equipment possible

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Pollution degree

3

Over voltage category

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA