Aleta.hr
Main Product Image

A9N18385

Code: 1694675

ManufacturerRAZNO
Catalog numberA9N18385
Type
EAN code3606480379567

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Release characteristic

D

Number of protected poles

2

Rated current

125A

Voltage type

AC

Rated voltage

415V

Over voltage category

4

Built-in depth

44mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Yes

Rated insulation voltage Ui

500V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Explosion-proof

No

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Ambient temperature during operating

-25 - 70°C

Connectable conductor cross section multi-wired

1 - 35mm²

Width in number of modular spacings

3

Concurrently switching neutral conductor

Yes

Flush-mounted installation

No

Connectable conductor cross section solid-core

1.5 - 50mm²

Frequency

50 - 60Hz

Rated impulse withstand voltage Uimp

6kV

Degree of protection (IP)

IP20


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

A9N18385

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Release characteristic

D

Number of protected poles

2

Rated current

125A

Voltage type

AC

Rated voltage

415V

Over voltage category

4

Built-in depth

44mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Rated insulation voltage Ui

500V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Explosion-proof

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section multi-wired

1 .. 35mm²

Width in number of modular spacings

3

Concurrently switching neutral conductor

Flush-mounted installation

Connectable conductor cross section solid-core

1.5 .. 50mm²

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

6kV

Degree of protection (IP)

IP20