Technical specifications

Release characteristic

C

Built-in depth

44mm

Number of poles (total)

3

Number of protected poles

3

Rated current

80A

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Pollution degree

3

Current limiting class

3

Concurrently switching neutral conductor

No

Over voltage category

4

Flush-mounted installation

No

Frequency

50 - 60Hz

Additional equipment possible

Yes

Width in number of modular spacings

4.5

Connectable conductor cross section multi-wired

1 - 35mm²

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 - 70°C

Explosion-proof

No

Connectable conductor cross section solid-core

1.5 - 50mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

A9N18365

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristic

C

Built-in depth

44mm

Number of poles (total)

3

Number of protected poles

3

Rated current

80A

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Pollution degree

3

Current limiting class

3

Concurrently switching neutral conductor

Over voltage category

4

Flush-mounted installation

Frequency

50 .. 60Hz

Additional equipment possible

Width in number of modular spacings

4.5

Connectable conductor cross section multi-wired

1 .. 35mm²

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 70°C

Explosion-proof

Connectable conductor cross section solid-core

1.5 .. 50mm²