Aleta.hr
Main Product Image

A9N18359

Code: 1694655

ManufacturerRAZNO
Catalog numberA9N18359
Type
EAN code3606480379338

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

44mm

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

1

Number of protected poles

1

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

3kA

Rated current

125A

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Current limiting class

3

Frequency

50 - 60Hz

Flush-mounted installation

No

Rated voltage

415V

Concurrently switching neutral conductor

No

Additional equipment possible

Yes

Over voltage category

4

Degree of protection (IP)

IP20

Width in number of modular spacings

1.5

Connectable conductor cross section multi-wired

1 - 35mm²

Explosion-proof

No

Connectable conductor cross section solid-core

1.5 - 50mm²

Pollution degree

3

Ambient temperature during operating

-25 - 70°C


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

A9N18359

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

44mm

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

1

Number of protected poles

1

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

3kA

Rated current

125A

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Current limiting class

3

Frequency

50 .. 60Hz

Flush-mounted installation

Rated voltage

415V

Concurrently switching neutral conductor

Additional equipment possible

Over voltage category

4

Degree of protection (IP)

IP20

Width in number of modular spacings

1.5

Connectable conductor cross section multi-wired

1 .. 35mm²

Explosion-proof

Connectable conductor cross section solid-core

1.5 .. 50mm²

Pollution degree

3

Ambient temperature during operating

-25 .. 70°C

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.