Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration TN-C
No
System configuration TN
No
System configuration TN-S
Yes
System configuration IT
No
Number of conductors (without earthing)
4
System configuration TN-C-S
No
Nominal discharge surge current (8/20)
20kA
System configuration TT
Yes
Nominal voltage AC
400V
System configuration other
No
Max. continuous voltage AC
350V
System configuration DC
No
Max. discharge surge current (8/20)
65kA
Voltage protection level
1.5kV
Voltage protection level N-PE
1.5kV
Voltage protection level L-N
1.5kV
Max. overcurrent protection device, parallel connection (fuse)
80A
Max. overcurrent protection device, series connection (fuse)
80A
Leakage-current free
No
Integrated short-circuit protection
No
Short-circuit breaking capacity (Isccr)
50kA
Construction size
4 modular spacing
Max. conductor cross section flexible (fine-strand)
35mm²
Mounting method
DIN rail (top hat rail) 35 mm
Integrated backup fuse
No
Signalling at the device
Optic
Degree of protection (IP)
IP20
With remote signalling contact
Yes
Category type 2
Yes
Max. conductor cross section solid (solid, stranded)
35mm²
From same serie
A9L65601

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration TN-C
System configuration TN
System configuration TN-S
System configuration IT
Number of conductors (without earthing)
4
System configuration TN-C-S
Nominal discharge surge current (8/20)
20kA
System configuration TT
Nominal voltage AC
400V
System configuration other
Max. continuous voltage AC
350V
System configuration DC
Max. discharge surge current (8/20)
65kA
Voltage protection level
1.5kV
Voltage protection level N-PE
1.5kV
Voltage protection level L-N
1.5kV
Max. overcurrent protection device, parallel connection (fuse)
80A
Max. overcurrent protection device, series connection (fuse)
80A
Leakage-current free
Integrated short-circuit protection
Short-circuit breaking capacity (Isccr)
50kA
Construction size
4 modular spacing
Max. conductor cross section flexible (fine-strand)
35mm²
Mounting method
DIN rail (top hat rail) 35 mm
Integrated backup fuse
Signalling at the device
Optic
Degree of protection (IP)
IP20
With remote signalling contact
Category type 2
Max. conductor cross section solid (solid, stranded)
35mm²