Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration IT
No
System configuration DC
No
System configuration TN-C
No
System configuration TN-S
Yes
System configuration TT
Yes
System configuration TN
No
Max. overcurrent protection device, series connection (fuse)
80A
Max. continuous voltage AC
350V
Max. conductor cross section flexible (fine-strand)
35mm²
Integrated short-circuit protection
No
Max. discharge surge current (8/20)
65kA
System configuration other
No
Nominal voltage AC
350V
Voltage protection level L-N
1.5kV
Number of conductors (without earthing)
1
Category type 2
Yes
Max. overcurrent protection device, parallel connection (fuse)
80A
Max. conductor cross section solid (solid, stranded)
35mm²
With remote signalling contact
Yes
Leakage-current free
No
Short-circuit breaking capacity (Isccr)
50kA
Construction size
2 modular spacing
Signalling at the device
Optic
Voltage protection level N-PE
1.5kV
System configuration TN-C-S
No
Integrated backup fuse
No
Degree of protection (IP)
IP20
Voltage protection level
1.5kV
Mounting method
DIN rail (top hat rail) 35 mm
Nominal discharge surge current (8/20)
20kA
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
A9L65501
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration IT
System configuration DC
System configuration TN-C
System configuration TN-S
System configuration TT
System configuration TN
Max. overcurrent protection device, series connection (fuse)
80A
Max. continuous voltage AC
350V
Max. conductor cross section flexible (fine-strand)
35mm²
Integrated short-circuit protection
Max. discharge surge current (8/20)
65kA
System configuration other
Nominal voltage AC
350V
Voltage protection level L-N
1.5kV
Number of conductors (without earthing)
1
Category type 2
Max. overcurrent protection device, parallel connection (fuse)
80A
Max. conductor cross section solid (solid, stranded)
35mm²
With remote signalling contact
Leakage-current free
Short-circuit breaking capacity (Isccr)
50kA
Construction size
2 modular spacing
Signalling at the device
Optic
Voltage protection level N-PE
1.5kV
System configuration TN-C-S
Integrated backup fuse
Degree of protection (IP)
IP20
Voltage protection level
1.5kV
Mounting method
DIN rail (top hat rail) 35 mm
Nominal discharge surge current (8/20)
20kA
From same serie