Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration DC
No
System configuration IT
No
System configuration other
No
Number of conductors (without earthing)
3
Max. discharge surge current (8/20)
65kA
Nominal discharge surge current (8/20)
20kA
Max. continuous voltage AC
350V
Max. overcurrent protection device, series connection (fuse)
80A
System configuration TN-S
No
Voltage protection level N-PE
1.5kV
System configuration TN-C
Yes
Max. conductor cross section solid (solid, stranded)
35mm²
Construction size
4 modular spacing
System configuration TN
No
Leakage-current free
No
Nominal voltage AC
350V
Max. conductor cross section flexible (fine-strand)
35mm²
Max. overcurrent protection device, parallel connection (fuse)
80A
System configuration TN-C-S
No
Voltage protection level L-N
1.5kV
Integrated short-circuit protection
No
Degree of protection (IP)
IP20
Integrated backup fuse
No
Voltage protection level
1.5kV
Short-circuit breaking capacity (Isccr)
50kA
Category type 2
Yes
System configuration TT
No
Signalling at the device
Optic
With remote signalling contact
Yes
Mounting method
DIN rail (top hat rail) 35 mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
A9L65301
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration DC
System configuration IT
System configuration other
Number of conductors (without earthing)
3
Max. discharge surge current (8/20)
65kA
Nominal discharge surge current (8/20)
20kA
Max. continuous voltage AC
350V
Max. overcurrent protection device, series connection (fuse)
80A
System configuration TN-S
Voltage protection level N-PE
1.5kV
System configuration TN-C
Max. conductor cross section solid (solid, stranded)
35mm²
Construction size
4 modular spacing
System configuration TN
Leakage-current free
Nominal voltage AC
350V
Max. conductor cross section flexible (fine-strand)
35mm²
Max. overcurrent protection device, parallel connection (fuse)
80A
System configuration TN-C-S
Voltage protection level L-N
1.5kV
Integrated short-circuit protection
Degree of protection (IP)
IP20
Integrated backup fuse
Voltage protection level
1.5kV
Short-circuit breaking capacity (Isccr)
50kA
Category type 2
System configuration TT
Signalling at the device
Optic
With remote signalling contact
Mounting method
DIN rail (top hat rail) 35 mm