Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage DC

-V

Nominal voltage DC

-V

Max. PV-voltage

-V

System configuration DC

No

System configuration IT

No

System configuration TN

No

System configuration TN-C

Yes

System configuration TN-C-S

No

System configuration TN-S

No

System configuration TT

No

Number of conductors (without earthing)

2

System configuration other

No

Nominal voltage AC

350V

Nominal discharge surge current (8/20)

20kA

Max. continuous voltage AC

350V

Voltage protection level

1.5kV

Max. discharge surge current (8/20)

65kA

Voltage protection level N-PE

1.5kV

Voltage protection level L-N

1.5kV

Max. overcurrent protection device, series connection (fuse)

80A

Integrated short-circuit protection

No

Max. overcurrent protection device, parallel connection (fuse)

80A

Integrated backup fuse

No

Short-circuit breaking capacity (Isccr)

50kA

Construction size

2 modular spacing

Leakage-current free

No

Mounting method

DIN rail (top hat rail) 35 mm

Max. conductor cross section solid (solid, stranded)

25mm²

Max. conductor cross section flexible (fine-strand)

16mm²

Degree of protection (IP)

IP20

With remote signalling contact

Yes

Signalling at the device

Optic

Category type 2

Yes


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

A9L65201

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage DC

-V

Nominal voltage DC

-V

Max. PV-voltage

-V

System configuration DC

System configuration IT

System configuration TN

System configuration TN-C

System configuration TN-C-S

System configuration TN-S

System configuration TT

Number of conductors (without earthing)

2

System configuration other

Nominal voltage AC

350V

Nominal discharge surge current (8/20)

20kA

Max. continuous voltage AC

350V

Voltage protection level

1.5kV

Max. discharge surge current (8/20)

65kA

Voltage protection level N-PE

1.5kV

Voltage protection level L-N

1.5kV

Max. overcurrent protection device, series connection (fuse)

80A

Integrated short-circuit protection

Max. overcurrent protection device, parallel connection (fuse)

80A

Integrated backup fuse

Short-circuit breaking capacity (Isccr)

50kA

Construction size

2 modular spacing

Leakage-current free

Mounting method

DIN rail (top hat rail) 35 mm

Max. conductor cross section solid (solid, stranded)

25mm²

Max. conductor cross section flexible (fine-strand)

16mm²

Degree of protection (IP)

IP20

With remote signalling contact

Signalling at the device

Optic

Category type 2

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.