Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
Number of conductors (without earthing)
4
Nominal discharge surge current (8/20)
15kA
System configuration other
No
Nominal voltage AC
400V
System configuration TN
No
System configuration IT
No
Max. discharge surge current (8/20)
40kA
System configuration DC
No
System configuration TN-C
No
Max. continuous voltage AC
350V
System configuration TT
Yes
Max. overcurrent protection device, parallel connection (fuse)
63A
Max. overcurrent protection device, series connection (fuse)
80A
Voltage protection level L-N
1.4kV
Integrated short-circuit protection
No
Voltage protection level
1.4kV
Leakage-current free
No
Mounting method
DIN rail (top hat rail) 35 mm
System configuration TN-C-S
No
Short-circuit breaking capacity (Isccr)
50kA
Max. conductor cross section flexible (fine-strand)
35mm²
Voltage protection level N-PE
1.4kV
Max. conductor cross section solid (solid, stranded)
35mm²
Integrated backup fuse
No
Construction size
4 modular spacing
Signalling at the device
Optic
Degree of protection (IP)
IP20
Category type 2
Yes
With remote signalling contact
No
System configuration TN-S
Yes
From same serie
A9L40600

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
Number of conductors (without earthing)
4
Nominal discharge surge current (8/20)
15kA
System configuration other
Nominal voltage AC
400V
System configuration TN
System configuration IT
Max. discharge surge current (8/20)
40kA
System configuration DC
System configuration TN-C
Max. continuous voltage AC
350V
System configuration TT
Max. overcurrent protection device, parallel connection (fuse)
63A
Max. overcurrent protection device, series connection (fuse)
80A
Voltage protection level L-N
1.4kV
Integrated short-circuit protection
Voltage protection level
1.4kV
Leakage-current free
Mounting method
DIN rail (top hat rail) 35 mm
System configuration TN-C-S
Short-circuit breaking capacity (Isccr)
50kA
Max. conductor cross section flexible (fine-strand)
35mm²
Voltage protection level N-PE
1.4kV
Max. conductor cross section solid (solid, stranded)
35mm²
Integrated backup fuse
Construction size
4 modular spacing
Signalling at the device
Optic
Degree of protection (IP)
IP20
Category type 2
With remote signalling contact
System configuration TN-S
From same serie
We use cookies to enhance your experience.