Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration DC
No
System configuration TN
No
System configuration TN-C
No
System configuration other
No
System configuration TT
Yes
Max. discharge surge current (8/20)
40kA
System configuration IT
No
Max. continuous voltage AC
350V
Max. overcurrent protection device, series connection (fuse)
80A
System configuration TN-C-S
No
Short-circuit breaking capacity (Isccr)
50kA
Integrated short-circuit protection
No
Voltage protection level
1.4kV
Number of conductors (without earthing)
1
Nominal voltage AC
400V
Voltage protection level N-PE
1.4kV
Nominal discharge surge current (8/20)
15kA
Leakage-current free
No
Integrated backup fuse
No
System configuration TN-S
Yes
Max. overcurrent protection device, parallel connection (fuse)
63A
Voltage protection level L-N
1.4kV
Mounting method
DIN rail (top hat rail) 35 mm
Max. conductor cross section flexible (fine-strand)
16mm²
With remote signalling contact
Yes
Max. conductor cross section solid (solid, stranded)
25mm²
Category type 2
Yes
Signalling at the device
Optic
Construction size
2 modular spacing
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
A9L40501

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration DC
System configuration TN
System configuration TN-C
System configuration other
System configuration TT
Max. discharge surge current (8/20)
40kA
System configuration IT
Max. continuous voltage AC
350V
Max. overcurrent protection device, series connection (fuse)
80A
System configuration TN-C-S
Short-circuit breaking capacity (Isccr)
50kA
Integrated short-circuit protection
Voltage protection level
1.4kV
Number of conductors (without earthing)
1
Nominal voltage AC
400V
Voltage protection level N-PE
1.4kV
Nominal discharge surge current (8/20)
15kA
Leakage-current free
Integrated backup fuse
System configuration TN-S
Max. overcurrent protection device, parallel connection (fuse)
63A
Voltage protection level L-N
1.4kV
Mounting method
DIN rail (top hat rail) 35 mm
Max. conductor cross section flexible (fine-strand)
16mm²
With remote signalling contact
Max. conductor cross section solid (solid, stranded)
25mm²
Category type 2
Signalling at the device
Optic
Construction size
2 modular spacing
Degree of protection (IP)
IP20
From same serie