Technical specifications

Max. continuous voltage DC

-V

Voltage protection level L-N

-kV

Nominal voltage DC

-V

Max. PV-voltage

400V

System configuration TN

No

System configuration DC

No

Number of conductors (without earthing)

4

Max. overcurrent protection device, parallel connection (fuse)

63A

Voltage protection level

1.6kV

System configuration other

No

Max. discharge surge current (8/20)

40kA

Integrated short-circuit protection

No

System configuration TN-C

Yes

Voltage protection level N-PE

1.4kV

Short-circuit breaking capacity (Isccr)

50kA

Integrated backup fuse

No

Nominal voltage AC

350V

System configuration IT

No

Leakage-current free

No

System configuration TN-S

No

System configuration TN-C-S

No

System configuration TT

No

Max. continuous voltage AC

350V

Nominal discharge surge current (8/20)

15kA

Max. overcurrent protection device, series connection (fuse)

80A

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

4 modular spacing

Signalling at the device

Optic

Category type 2

Yes

With remote signalling contact

No

Degree of protection (IP)

IP20

Max. conductor cross section solid (solid, stranded)

25mm²

Max. conductor cross section flexible (fine-strand)

16mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

A9L40400

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage DC

-V

Voltage protection level L-N

-kV

Nominal voltage DC

-V

Max. PV-voltage

400V

System configuration TN

System configuration DC

Number of conductors (without earthing)

4

Max. overcurrent protection device, parallel connection (fuse)

63A

Voltage protection level

1.6kV

System configuration other

Max. discharge surge current (8/20)

40kA

Integrated short-circuit protection

System configuration TN-C

Voltage protection level N-PE

1.4kV

Short-circuit breaking capacity (Isccr)

50kA

Integrated backup fuse

Nominal voltage AC

350V

System configuration IT

Leakage-current free

System configuration TN-S

System configuration TN-C-S

System configuration TT

Max. continuous voltage AC

350V

Nominal discharge surge current (8/20)

15kA

Max. overcurrent protection device, series connection (fuse)

80A

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

4 modular spacing

Signalling at the device

Optic

Category type 2

With remote signalling contact

Degree of protection (IP)

IP20

Max. conductor cross section solid (solid, stranded)

25mm²

Max. conductor cross section flexible (fine-strand)

16mm²