Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Voltage protection level L-N
-kV
Nominal voltage DC
-V
Max. PV-voltage
400V
System configuration TN
No
System configuration DC
No
Number of conductors (without earthing)
4
Max. overcurrent protection device, parallel connection (fuse)
63A
Voltage protection level
1.6kV
System configuration other
No
Max. discharge surge current (8/20)
40kA
Integrated short-circuit protection
No
System configuration TN-C
Yes
Voltage protection level N-PE
1.4kV
Short-circuit breaking capacity (Isccr)
50kA
Integrated backup fuse
No
Nominal voltage AC
350V
System configuration IT
No
Leakage-current free
No
System configuration TN-S
No
System configuration TN-C-S
No
System configuration TT
No
Max. continuous voltage AC
350V
Nominal discharge surge current (8/20)
15kA
Max. overcurrent protection device, series connection (fuse)
80A
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
4 modular spacing
Signalling at the device
Optic
Category type 2
Yes
With remote signalling contact
No
Degree of protection (IP)
IP20
Max. conductor cross section solid (solid, stranded)
25mm²
Max. conductor cross section flexible (fine-strand)
16mm²
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
A9L40400
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Voltage protection level L-N
-kV
Nominal voltage DC
-V
Max. PV-voltage
400V
System configuration TN
System configuration DC
Number of conductors (without earthing)
4
Max. overcurrent protection device, parallel connection (fuse)
63A
Voltage protection level
1.6kV
System configuration other
Max. discharge surge current (8/20)
40kA
Integrated short-circuit protection
System configuration TN-C
Voltage protection level N-PE
1.4kV
Short-circuit breaking capacity (Isccr)
50kA
Integrated backup fuse
Nominal voltage AC
350V
System configuration IT
Leakage-current free
System configuration TN-S
System configuration TN-C-S
System configuration TT
Max. continuous voltage AC
350V
Nominal discharge surge current (8/20)
15kA
Max. overcurrent protection device, series connection (fuse)
80A
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
4 modular spacing
Signalling at the device
Optic
Category type 2
With remote signalling contact
Degree of protection (IP)
IP20
Max. conductor cross section solid (solid, stranded)
25mm²
Max. conductor cross section flexible (fine-strand)
16mm²
From same serie
We use cookies to enhance your experience.