Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Voltage protection level L-N
-kV
Nominal voltage DC
-V
Voltage protection level N-PE
-kV
Max. PV-voltage
-V
System configuration DC
No
Number of conductors (without earthing)
3
System configuration TN-C
Yes
System configuration TN-S
No
System configuration other
No
System configuration TN
No
System configuration TT
No
Max. continuous voltage AC
350V
Nominal voltage AC
350V
Voltage protection level
1.4kV
Max. overcurrent protection device, parallel connection (fuse)
63A
System configuration TN-C-S
No
Integrated backup fuse
No
Short-circuit breaking capacity (Isccr)
50kA
System configuration IT
No
Leakage-current free
No
Mounting method
DIN rail (top hat rail) 35 mm
Max. conductor cross section solid (solid, stranded)
35mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Category type 2
Yes
Signalling at the device
Optic
Nominal discharge surge current (8/20)
15kA
With remote signalling contact
Yes
Degree of protection (IP)
IP20
Construction size
3 modular spacing
Max. overcurrent protection device, series connection (fuse)
80A
Max. discharge surge current (8/20)
40kA
Integrated short-circuit protection
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
A9L40301
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Voltage protection level L-N
-kV
Nominal voltage DC
-V
Voltage protection level N-PE
-kV
Max. PV-voltage
-V
System configuration DC
Number of conductors (without earthing)
3
System configuration TN-C
System configuration TN-S
System configuration other
System configuration TN
System configuration TT
Max. continuous voltage AC
350V
Nominal voltage AC
350V
Voltage protection level
1.4kV
Max. overcurrent protection device, parallel connection (fuse)
63A
System configuration TN-C-S
Integrated backup fuse
Short-circuit breaking capacity (Isccr)
50kA
System configuration IT
Leakage-current free
Mounting method
DIN rail (top hat rail) 35 mm
Max. conductor cross section solid (solid, stranded)
35mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Category type 2
Signalling at the device
Optic
Nominal discharge surge current (8/20)
15kA
With remote signalling contact
Degree of protection (IP)
IP20
Construction size
3 modular spacing
Max. overcurrent protection device, series connection (fuse)
80A
Max. discharge surge current (8/20)
40kA
Integrated short-circuit protection
From same serie