Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration IT
No
System configuration TN-C-S
No
System configuration TN-C
Yes
System configuration DC
No
System configuration TN-S
No
Number of conductors (without earthing)
2
System configuration other
No
Nominal voltage AC
350V
Voltage protection level
1.4kV
Nominal discharge surge current (8/20)
15kA
Voltage protection level L-N
1.4kV
Max. overcurrent protection device, series connection (fuse)
80A
Short-circuit breaking capacity (Isccr)
50kA
System configuration TN
No
Integrated short-circuit protection
No
Max. overcurrent protection device, parallel connection (fuse)
63A
Max. discharge surge current (8/20)
40kA
Leakage-current free
No
Max. continuous voltage AC
350V
Integrated backup fuse
No
Mounting method
DIN rail (top hat rail) 35 mm
With remote signalling contact
Yes
Construction size
2 modular spacing
Max. conductor cross section solid (solid, stranded)
25mm²
Degree of protection (IP)
IP20
Max. conductor cross section flexible (fine-strand)
16mm²
Category type 2
Yes
Voltage protection level N-PE
1.4kV
Signalling at the device
Optic
System configuration TT
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
A9L40201
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration IT
System configuration TN-C-S
System configuration TN-C
System configuration DC
System configuration TN-S
Number of conductors (without earthing)
2
System configuration other
Nominal voltage AC
350V
Voltage protection level
1.4kV
Nominal discharge surge current (8/20)
15kA
Voltage protection level L-N
1.4kV
Max. overcurrent protection device, series connection (fuse)
80A
Short-circuit breaking capacity (Isccr)
50kA
System configuration TN
Integrated short-circuit protection
Max. overcurrent protection device, parallel connection (fuse)
63A
Max. discharge surge current (8/20)
40kA
Leakage-current free
Max. continuous voltage AC
350V
Integrated backup fuse
Mounting method
DIN rail (top hat rail) 35 mm
With remote signalling contact
Construction size
2 modular spacing
Max. conductor cross section solid (solid, stranded)
25mm²
Degree of protection (IP)
IP20
Max. conductor cross section flexible (fine-strand)
16mm²
Category type 2
Voltage protection level N-PE
1.4kV
Signalling at the device
Optic
System configuration TT