Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration DC
No
System configuration IT
No
System configuration TN-C-S
No
System configuration TN
No
System configuration TN-C
Yes
System configuration TT
No
System configuration TN-S
No
System configuration other
No
Number of conductors (without earthing)
2
Max. discharge surge current (8/20)
40kA
Nominal discharge surge current (8/20)
15kA
Voltage protection level
1.4kV
Max. overcurrent protection device, parallel connection (fuse)
63A
Voltage protection level L-N
1.4kV
Voltage protection level N-PE
1.4kV
Max. continuous voltage AC
350V
Max. overcurrent protection device, series connection (fuse)
80A
Integrated backup fuse
No
Mounting method
DIN rail (top hat rail) 35 mm
Short-circuit breaking capacity (Isccr)
50kA
Integrated short-circuit protection
No
Leakage-current free
No
Construction size
2 modular spacing
Max. conductor cross section solid (solid, stranded)
25mm²
Category type 2
Yes
Max. conductor cross section flexible (fine-strand)
16mm²
With remote signalling contact
No
Signalling at the device
Optic
Degree of protection (IP)
IP20
Nominal voltage AC
350V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
A9L40200

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration DC
System configuration IT
System configuration TN-C-S
System configuration TN
System configuration TN-C
System configuration TT
System configuration TN-S
System configuration other
Number of conductors (without earthing)
2
Max. discharge surge current (8/20)
40kA
Nominal discharge surge current (8/20)
15kA
Voltage protection level
1.4kV
Max. overcurrent protection device, parallel connection (fuse)
63A
Voltage protection level L-N
1.4kV
Voltage protection level N-PE
1.4kV
Max. continuous voltage AC
350V
Max. overcurrent protection device, series connection (fuse)
80A
Integrated backup fuse
Mounting method
DIN rail (top hat rail) 35 mm
Short-circuit breaking capacity (Isccr)
50kA
Integrated short-circuit protection
Leakage-current free
Construction size
2 modular spacing
Max. conductor cross section solid (solid, stranded)
25mm²
Category type 2
Max. conductor cross section flexible (fine-strand)
16mm²
With remote signalling contact
Signalling at the device
Optic
Degree of protection (IP)
IP20
Nominal voltage AC
350V
From same serie