Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Voltage protection level N-PE
-kV
Max. PV-voltage
-V
System configuration TN-S
No
System configuration TN-C-S
No
System configuration TT
Yes
System configuration IT
No
Max. discharge surge current (8/20)
40kA
System configuration TN
No
System configuration DC
No
Nominal voltage AC
230V
System configuration TN-C
Yes
Number of conductors (without earthing)
1
Voltage protection level
1.4kV
Short-circuit breaking capacity (Isccr)
50kA
Voltage protection level L-N
1.4kV
Nominal discharge surge current (8/20)
15kA
Leakage-current free
No
Max. overcurrent protection device, parallel connection (fuse)
63A
Max. overcurrent protection device, series connection (fuse)
80A
Mounting method
DIN rail (top hat rail) 35 mm
Integrated short-circuit protection
No
System configuration other
No
Integrated backup fuse
No
Construction size
1 modular spacing
Category type 2
Yes
Signalling at the device
Optic
Degree of protection (IP)
IP20
Max. conductor cross section flexible (fine-strand)
35mm²
With remote signalling contact
Yes
Max. conductor cross section solid (solid, stranded)
35mm²
Max. continuous voltage AC
350V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
A9L40101
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Voltage protection level N-PE
-kV
Max. PV-voltage
-V
System configuration TN-S
System configuration TN-C-S
System configuration TT
System configuration IT
Max. discharge surge current (8/20)
40kA
System configuration TN
System configuration DC
Nominal voltage AC
230V
System configuration TN-C
Number of conductors (without earthing)
1
Voltage protection level
1.4kV
Short-circuit breaking capacity (Isccr)
50kA
Voltage protection level L-N
1.4kV
Nominal discharge surge current (8/20)
15kA
Leakage-current free
Max. overcurrent protection device, parallel connection (fuse)
63A
Max. overcurrent protection device, series connection (fuse)
80A
Mounting method
DIN rail (top hat rail) 35 mm
Integrated short-circuit protection
System configuration other
Integrated backup fuse
Construction size
1 modular spacing
Category type 2
Signalling at the device
Optic
Degree of protection (IP)
IP20
Max. conductor cross section flexible (fine-strand)
35mm²
With remote signalling contact
Max. conductor cross section solid (solid, stranded)
35mm²
Max. continuous voltage AC
350V
From same serie