Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Short-circuit-proof

Yes

Max. continuous voltage DC

-V

Nominal voltage DC

-V

Max. PV-voltage

-V

Type of poles

1+N/PE

System configuration

TT

System configuration DC

No

System configuration TN-C-S

No

Max. discharge surge current (8/20)

10kA

Voltage protection level

1.5kV

Category type 2

Yes

System configuration TN

No

System configuration other

No

Max. continuous voltage AC

275V

System configuration TT

Yes

Nominal discharge surge current (8/20)

10kA

Nominal voltage AC

230V

System configuration TN-S

Yes

Max. conductor cross section flexible (fine-strand)

16mm²

Number of conductors (without earthing)

1

Voltage protection level L-N

1.5kV

Integrated short-circuit protection

Yes

Max. conductor cross section solid (solid, stranded)

16mm²

Voltage protection level N-PE

1.5kV

System configuration IT

No

System configuration TN-C

No

Short-circuit breaking capacity (Isccr)

6kA

Integrated backup fuse

No

Mounting method

DIN rail (top hat rail) 35 mm

Leakage-current free

No

Signalling at the device

Optic

Construction size

2 modular spacing

Degree of protection (IP)

IP20

With remote signalling contact

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

A9L16617

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Short-circuit-proof

Max. continuous voltage DC

-V

Nominal voltage DC

-V

Max. PV-voltage

-V

Type of poles

1+N/PE

System configuration

TT

System configuration DC

System configuration TN-C-S

Max. discharge surge current (8/20)

10kA

Voltage protection level

1.5kV

Category type 2

System configuration TN

System configuration other

Max. continuous voltage AC

275V

System configuration TT

Nominal discharge surge current (8/20)

10kA

Nominal voltage AC

230V

System configuration TN-S

Max. conductor cross section flexible (fine-strand)

16mm²

Number of conductors (without earthing)

1

Voltage protection level L-N

1.5kV

Integrated short-circuit protection

Max. conductor cross section solid (solid, stranded)

16mm²

Voltage protection level N-PE

1.5kV

System configuration IT

System configuration TN-C

Short-circuit breaking capacity (Isccr)

6kA

Integrated backup fuse

Mounting method

DIN rail (top hat rail) 35 mm

Leakage-current free

Signalling at the device

Optic

Construction size

2 modular spacing

Degree of protection (IP)

IP20

With remote signalling contact

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.