Max. continuous voltage DC

-V

Nominal voltage DC

-V

Max. PV-voltage

-V

System configuration DC

No

System configuration TN

No

System configuration IT

No

System configuration TN-C-S

No

Max. continuous voltage AC

350V

System configuration TN-S

Yes

Nominal discharge surge current (8/20)

2.5kA

System configuration TT

Yes

System configuration other

No

Nominal voltage AC

230V

Voltage protection level

1kV

Max. discharge surge current (8/20)

8kA

Number of conductors (without earthing)

1

Voltage protection level L-N

1.1kV

System configuration TN-C

No

Voltage protection level N-PE

1.4kV

Max. overcurrent protection device, series connection (fuse)

80A

Short-circuit breaking capacity (Isccr)

50kA

Max. overcurrent protection device, parallel connection (fuse)

25A

Leakage-current free

No

Integrated short-circuit protection

No

Integrated backup fuse

No

Signalling at the device

Optic

Max. conductor cross section solid (solid, stranded)

35mm²

Category type 2

Yes

Construction size

2 modular spacing

Degree of protection (IP)

IP20

Mounting method

DIN rail (top hat rail) 35 mm

Max. conductor cross section flexible (fine-strand)

35mm²

With remote signalling contact

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

A9L08500

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage DC

-V

Nominal voltage DC

-V

Max. PV-voltage

-V

System configuration DC

System configuration TN

System configuration IT

System configuration TN-C-S

Max. continuous voltage AC

350V

System configuration TN-S

Nominal discharge surge current (8/20)

2.5kA

System configuration TT

System configuration other

Nominal voltage AC

230V

Voltage protection level

1kV

Max. discharge surge current (8/20)

8kA

Number of conductors (without earthing)

1

Voltage protection level L-N

1.1kV

System configuration TN-C

Voltage protection level N-PE

1.4kV

Max. overcurrent protection device, series connection (fuse)

80A

Short-circuit breaking capacity (Isccr)

50kA

Max. overcurrent protection device, parallel connection (fuse)

25A

Leakage-current free

Integrated short-circuit protection

Integrated backup fuse

Signalling at the device

Optic

Max. conductor cross section solid (solid, stranded)

35mm²

Category type 2

Construction size

2 modular spacing

Degree of protection (IP)

IP20

Mounting method

DIN rail (top hat rail) 35 mm

Max. conductor cross section flexible (fine-strand)

35mm²

With remote signalling contact