Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Voltage protection level L-N
1kV
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration IT
No
System configuration DC
No
System configuration TT
No
Nominal discharge surge current (8/20)
2.5kA
System configuration TN-S
No
System configuration TN-C-S
No
System configuration TN-C
Yes
Nominal voltage AC
350V
Max. discharge surge current (8/20)
8kA
Max. continuous voltage AC
350V
Voltage protection level
1.2kV
Number of conductors (without earthing)
4
Voltage protection level N-PE
1.2kV
Integrated short-circuit protection
No
Max. overcurrent protection device, parallel connection (fuse)
25A
Max. overcurrent protection device, series connection (fuse)
80A
Short-circuit breaking capacity (Isccr)
50kA
Construction size
4 modular spacing
Integrated backup fuse
No
Max. conductor cross section solid (solid, stranded)
25mm²
System configuration TN
No
Mounting method
DIN rail (top hat rail) 35 mm
Leakage-current free
No
Max. conductor cross section flexible (fine-strand)
16mm²
Signalling at the device
Optic
Category type 2
Yes
With remote signalling contact
No
Degree of protection (IP)
IP20
System configuration other
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
A9L08400
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Voltage protection level L-N
1kV
Nominal voltage DC
-V
Max. PV-voltage
-V
System configuration IT
System configuration DC
System configuration TT
Nominal discharge surge current (8/20)
2.5kA
System configuration TN-S
System configuration TN-C-S
System configuration TN-C
Nominal voltage AC
350V
Max. discharge surge current (8/20)
8kA
Max. continuous voltage AC
350V
Voltage protection level
1.2kV
Number of conductors (without earthing)
4
Voltage protection level N-PE
1.2kV
Integrated short-circuit protection
Max. overcurrent protection device, parallel connection (fuse)
25A
Max. overcurrent protection device, series connection (fuse)
80A
Short-circuit breaking capacity (Isccr)
50kA
Construction size
4 modular spacing
Integrated backup fuse
Max. conductor cross section solid (solid, stranded)
25mm²
System configuration TN
Mounting method
DIN rail (top hat rail) 35 mm
Leakage-current free
Max. conductor cross section flexible (fine-strand)
16mm²
Signalling at the device
Optic
Category type 2
With remote signalling contact
Degree of protection (IP)
IP20
System configuration other
From same serie