Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Voltage protection level L-N
1kV
Nominal voltage DC
-V
Voltage protection level N-PE
-kV
Max. PV-voltage
-V
Number of conductors (without earthing)
1
Voltage protection level
1kV
System configuration TT
Yes
Nominal voltage AC
230V
System configuration TN
No
System configuration other
No
System configuration DC
No
Short-circuit breaking capacity (Isccr)
50kA
System configuration TN-S
No
Max. overcurrent protection device, parallel connection (fuse)
25A
Max. discharge surge current (8/20)
8kA
Max. overcurrent protection device, series connection (fuse)
80A
Nominal discharge surge current (8/20)
2.5kA
Max. continuous voltage AC
350V
System configuration TN-C
Yes
Integrated short-circuit protection
No
System configuration IT
No
System configuration TN-C-S
No
Integrated backup fuse
No
With remote signalling contact
No
Max. conductor cross section solid (solid, stranded)
35mm²
Degree of protection (IP)
IP20
Construction size
2 modular spacing
Max. conductor cross section flexible (fine-strand)
35mm²
Leakage-current free
No
Signalling at the device
Optic
Category type 2
Yes
Mounting method
DIN rail (top hat rail) 35 mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
A9L08100
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
Max. continuous voltage DC
-V
Voltage protection level L-N
1kV
Nominal voltage DC
-V
Voltage protection level N-PE
-kV
Max. PV-voltage
-V
Number of conductors (without earthing)
1
Voltage protection level
1kV
System configuration TT
Nominal voltage AC
230V
System configuration TN
System configuration other
System configuration DC
Short-circuit breaking capacity (Isccr)
50kA
System configuration TN-S
Max. overcurrent protection device, parallel connection (fuse)
25A
Max. discharge surge current (8/20)
8kA
Max. overcurrent protection device, series connection (fuse)
80A
Nominal discharge surge current (8/20)
2.5kA
Max. continuous voltage AC
350V
System configuration TN-C
Integrated short-circuit protection
System configuration IT
System configuration TN-C-S
Integrated backup fuse
With remote signalling contact
Max. conductor cross section solid (solid, stranded)
35mm²
Degree of protection (IP)
IP20
Construction size
2 modular spacing
Max. conductor cross section flexible (fine-strand)
35mm²
Leakage-current free
Signalling at the device
Optic
Category type 2
Mounting method
DIN rail (top hat rail) 35 mm
From same serie