  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage DC

-V

Voltage protection level L-N

-kV

Max. conductor cross section flexible (fine-strand)

16mm²

Max. conductor cross section solid (solid, stranded)

25mm²

Nominal voltage DC

-V

Voltage protection level N-PE

1.4kV

Max. PV-voltage

400V

System configuration DC

No

System configuration IT

No

Integrated short-circuit protection

No

System configuration TT

Yes

Max. continuous voltage AC

260V

System configuration TN-S

No

System configuration TN

Yes

System configuration TN-C-S

No

Voltage protection level

1.4kV

Degree of protection (IP)

IP20

Category type 2

Yes

Mounting method

On basic element

System configuration other

No

System configuration TN-C

No

Max. discharge surge current (8/20)

65kA

Leakage-current free

No

Nominal voltage AC

230V

Integrated backup fuse

No

With remote signalling contact

No

Construction size

1 modular spacing

Nominal discharge surge current (8/20)

20kA

Signalling at the device

Optic


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

A9L00002

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • SCHNEIDER

Technical specifications

Max. continuous voltage DC

-V

Voltage protection level L-N

-kV

Max. conductor cross section flexible (fine-strand)

16mm²

Max. conductor cross section solid (solid, stranded)

25mm²

Nominal voltage DC

-V

Voltage protection level N-PE

1.4kV

Max. PV-voltage

400V

System configuration DC

System configuration IT

Integrated short-circuit protection

System configuration TT

Max. continuous voltage AC

260V

System configuration TN-S

System configuration TN

System configuration TN-C-S

Voltage protection level

1.4kV

Degree of protection (IP)

IP20

Category type 2

Mounting method

On basic element

System configuration other

System configuration TN-C

Max. discharge surge current (8/20)

65kA

Leakage-current free

Nominal voltage AC

230V

Integrated backup fuse

With remote signalling contact

Construction size

1 modular spacing

Nominal discharge surge current (8/20)

20kA

Signalling at the device

Optic

From same serie