Aleta.hr
Main Product Image

A9F94232

Code: 1694321

ManufacturerRAZNO
Catalog numberA9F94232
Type
EAN code3606480084607

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristic

C

Built-in depth

44.5mm

Number of protected poles

2

Number of poles (total)

2

Rated current

32A

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Current limiting class

3

Frequency

50 - 60Hz

Concurrently switching neutral conductor

No

Over voltage category

4

Pollution degree

3

Degree of protection (IP)

IP20

Additional equipment possible

Yes

Width in number of modular spacings

2

Ambient temperature during operating

-35 - 70°C

Connectable conductor cross section multi-wired

1 - 25mm²

Rated voltage

400V

Explosion-proof

No

Connectable conductor cross section solid-core

1 - 35mm²

Flush-mounted installation

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

A9F94232

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Release characteristic

C

Built-in depth

44.5mm

Number of protected poles

2

Number of poles (total)

2

Rated current

32A

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Voltage type

AC/DC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Current limiting class

3

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Over voltage category

4

Pollution degree

3

Degree of protection (IP)

IP20

Additional equipment possible

Width in number of modular spacings

2

Ambient temperature during operating

-35 .. 70°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated voltage

400V

Explosion-proof

Connectable conductor cross section solid-core

1 .. 35mm²

Flush-mounted installation

From same serie