Aleta.hr
Main Product Image

A9F84202

Code: 1694030

ManufacturerRAZNO
Catalog numberA9F84202
Type
EAN code3606480082566

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of protected poles

2

Built-in depth

44.5mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC/DC

Rated voltage

400V

Number of poles (total)

2

Release characteristic

C

Pollution degree

3

Degree of protection (IP)

IP20

Current limiting class

3

Frequency

50 - 60Hz

Additional equipment possible

Yes

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

70kA

Flush-mounted installation

No

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Over voltage category

4

Ambient temperature during operating

-35 - 70°C

Rated insulation voltage Ui

500V

Explosion-proof

No

Rated impulse withstand voltage Uimp

6kV

Rated current

2A

Connectable conductor cross section solid-core

1 - 25mm²

Concurrently switching neutral conductor

No

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

70kA

Connectable conductor cross section multi-wired

1 - 16mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

A9F84202

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Number of protected poles

2

Built-in depth

44.5mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC/DC

Rated voltage

400V

Number of poles (total)

2

Release characteristic

C

Pollution degree

3

Degree of protection (IP)

IP20

Current limiting class

3

Frequency

50 .. 60Hz

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

70kA

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Over voltage category

4

Ambient temperature during operating

-35 .. 70°C

Rated insulation voltage Ui

500V

Explosion-proof

Rated impulse withstand voltage Uimp

6kV

Rated current

2A

Connectable conductor cross section solid-core

1 .. 25mm²

Concurrently switching neutral conductor

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

70kA

Connectable conductor cross section multi-wired

1 .. 16mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.