Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
System configuration DC
No
System configuration TN-C
No
System configuration TN-C-S
No
System configuration TN
No
System configuration IT
Yes
Nominal voltage DC
0V
Max. continuous voltage DC
0V
Max. overcurrent protection device, parallel connection (fuse)
0A
Number of conductors (without earthing)
1
Integrated backup fuse
No
Mounting method
On basic element
Construction size
Other
Max. conductor cross section flexible (fine-strand)
150mm²
Integrated short-circuit protection
Yes
Leakage-current free
No
Short-circuit breaking capacity (Isccr)
40kA
Degree of protection (IP)
Other
Nominal voltage AC
660V
Max. conductor cross section solid (solid, stranded)
150mm²
Signalling at the device
Optic
Voltage protection level N-PE
0.66kV
Nominal discharge surge current (8/20)
40kA
Voltage protection level
1.6kV
Max. PV-voltage
0V
Max. overcurrent protection device, series connection (fuse)
0A
Max. continuous voltage AC
1000V
System configuration TN-S
No
Category type 2
No
System configuration other
No
Voltage protection level L-N
1kV
With remote signalling contact
No
Max. discharge surge current (8/20)
40kA
System configuration TT
No
Integrated short-circuit protection selective to fuse gG
0A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
50172
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
System configuration DC
System configuration TN-C
System configuration TN-C-S
System configuration TN
System configuration IT
Nominal voltage DC
0V
Max. continuous voltage DC
0V
Max. overcurrent protection device, parallel connection (fuse)
0A
Number of conductors (without earthing)
1
Integrated backup fuse
Mounting method
On basic element
Construction size
Other
Max. conductor cross section flexible (fine-strand)
150mm²
Integrated short-circuit protection
Leakage-current free
Short-circuit breaking capacity (Isccr)
40kA
Degree of protection (IP)
Other
Nominal voltage AC
660V
Max. conductor cross section solid (solid, stranded)
150mm²
Signalling at the device
Optic
Voltage protection level N-PE
0.66kV
Nominal discharge surge current (8/20)
40kA
Voltage protection level
1.6kV
Max. PV-voltage
0V
Max. overcurrent protection device, series connection (fuse)
0A
Max. continuous voltage AC
1000V
System configuration TN-S
Category type 2
System configuration other
Voltage protection level L-N
1kV
With remote signalling contact
Max. discharge surge current (8/20)
40kA
System configuration TT
Integrated short-circuit protection selective to fuse gG
0A
From same serie