Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
System configuration DC
No
System configuration IT
Yes
System configuration TT
No
System configuration TN-C
No
System configuration TN
No
System configuration TN-S
No
System configuration other
No
System configuration TN-C-S
No
Max. discharge surge current (8/20)
40kA
Nominal discharge surge current (8/20)
40kA
Nominal voltage AC
440V
Number of conductors (without earthing)
1
Max. PV-voltage
0V
Max. continuous voltage DC
0V
Max. overcurrent protection device, parallel connection (fuse)
0A
Nominal voltage DC
0V
Max. overcurrent protection device, series connection (fuse)
0A
Max. continuous voltage AC
660V
Short-circuit breaking capacity (Isccr)
40kA
Integrated short-circuit protection
Yes
Voltage protection level N-PE
0.38kV
Integrated short-circuit protection selective to fuse gG
0A
Construction size
Other
Integrated backup fuse
No
Max. conductor cross section solid (solid, stranded)
150mm²
With remote signalling contact
No
Voltage protection level
1.1kV
Max. conductor cross section flexible (fine-strand)
150mm²
Voltage protection level L-N
0.66kV
Category type 2
No
Degree of protection (IP)
Other
Leakage-current free
No
Signalling at the device
Optic
Mounting method
On basic element
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
50171

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- SCHNEIDER
Technical specifications
System configuration DC
System configuration IT
System configuration TT
System configuration TN-C
System configuration TN
System configuration TN-S
System configuration other
System configuration TN-C-S
Max. discharge surge current (8/20)
40kA
Nominal discharge surge current (8/20)
40kA
Nominal voltage AC
440V
Number of conductors (without earthing)
1
Max. PV-voltage
0V
Max. continuous voltage DC
0V
Max. overcurrent protection device, parallel connection (fuse)
0A
Nominal voltage DC
0V
Max. overcurrent protection device, series connection (fuse)
0A
Max. continuous voltage AC
660V
Short-circuit breaking capacity (Isccr)
40kA
Integrated short-circuit protection
Voltage protection level N-PE
0.38kV
Integrated short-circuit protection selective to fuse gG
0A
Construction size
Other
Integrated backup fuse
Max. conductor cross section solid (solid, stranded)
150mm²
With remote signalling contact
Voltage protection level
1.1kV
Max. conductor cross section flexible (fine-strand)
150mm²
Voltage protection level L-N
0.66kV
Category type 2
Degree of protection (IP)
Other
Leakage-current free
Signalling at the device
Optic
Mounting method
On basic element
From same serie