![Main Product Image](https://assets.aleta.hr/415x415/6305e96c-1d41-49f8-bea0-c423feb07aaf.webp)
![Main Product Image](https://assets.aleta.hr/415x415/6305e96c-1d41-49f8-bea0-c423feb07aaf.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
1250A
Adjustment range undelayed short-circuit release
2500 - 18750A
Overload release current setting
500 - 1250A
Type of electrical connection of main circuit
Screw connection
Integrated earth fault protection
No
Adjustment range short-term delayed short-circuit release
750 - 12500A
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Number of poles
3
With switched-off indicator
Yes
With integrated under voltage release
No
Position of connection for main current circuit
Front side
Type of control element
Toggle
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Yes
Motor drive integrated
No
Degree of protection (IP)
IP40
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33564
![Main Product Image](https://assets.aleta.hr/300x300/a7e9b42c-3ce8-4260-9db8-7ca19a844464_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated permanent current Iu
1250A
Adjustment range undelayed short-circuit release
2500 .. 18750A
Overload release current setting
500 .. 1250A
Type of electrical connection of main circuit
Screw connection
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
750 .. 12500A
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Number of poles
3
With switched-off indicator
With integrated under voltage release
Position of connection for main current circuit
Front side
Type of control element
Toggle
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Motor drive integrated
Degree of protection (IP)
IP40
Complete device with protection unit
From same serie