![Main Product Image](https://assets.aleta.hr/415x415/4d468170-7fcd-4dbd-8b82-32b4638a17d4.webp)
![Main Product Image](https://assets.aleta.hr/415x415/4d468170-7fcd-4dbd-8b82-32b4638a17d4.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Rated permanent current Iu
1000A
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
2000 - 15000A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Screw connection
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
DIN rail (top hat rail) mounting optional
No
Adjustment range short-term delayed short-circuit release
600 - 10000A
Overload release current setting
400 - 1000A
Device construction
Built-in device fixed built-in technique
Degree of protection (IP)
IP40
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
0
Type of control element
Toggle
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Number of auxiliary contacts as normally open contact
0
Number of poles
3
With switched-off indicator
Yes
Position of connection for main current circuit
Front side
With integrated under voltage release
No
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33559
![Main Product Image](https://assets.aleta.hr/300x300/eebb2608-c51e-4268-be4f-4053cc01edea_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Rated permanent current Iu
1000A
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
2000 .. 15000A
Integrated earth fault protection
Type of electrical connection of main circuit
Screw connection
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
600 .. 10000A
Overload release current setting
400 .. 1000A
Device construction
Built-in device fixed built-in technique
Degree of protection (IP)
IP40
Motor drive optional
Number of auxiliary contacts as change-over contact
0
Type of control element
Toggle
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Number of auxiliary contacts as normally open contact
0
Number of poles
3
With switched-off indicator
Position of connection for main current circuit
Front side
With integrated under voltage release
Complete device with protection unit
From same serie
We use cookies to enhance your experience.