![Main Product Image](https://assets.aleta.hr/415x415/95fe00cf-b219-4582-9996-5883594e3cf7.webp)
![Main Product Image](https://assets.aleta.hr/415x415/95fe00cf-b219-4582-9996-5883594e3cf7.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Rated voltage
690 - 690V
Rated permanent current Iu
800A
Type of electrical connection of main circuit
Screw connection
Adjustment range short-term delayed short-circuit release
480 - 8000A
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
320 - 800A
Adjustment range undelayed short-circuit release
1600 - 12000A
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
No
Type of control element
Toggle
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Motor drive integrated
No
Complete device with protection unit
Yes
With integrated under voltage release
No
Position of connection for main current circuit
Front side
Degree of protection (IP)
IP40
With switched-off indicator
Yes
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33556
![Main Product Image](https://assets.aleta.hr/300x300/58f93a4a-02a3-4e0c-9128-74293e8d56bf_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Rated voltage
690 .. 690V
Rated permanent current Iu
800A
Type of electrical connection of main circuit
Screw connection
Adjustment range short-term delayed short-circuit release
480 .. 8000A
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
320 .. 800A
Adjustment range undelayed short-circuit release
1600 .. 12000A
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
Type of control element
Toggle
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Motor drive integrated
Complete device with protection unit
With integrated under voltage release
Position of connection for main current circuit
Front side
Degree of protection (IP)
IP40
With switched-off indicator
Motor drive optional
From same serie
We use cookies to enhance your experience.