![Main Product Image](https://assets.aleta.hr/415x415/95fe00cf-b219-4582-9996-5883594e3cf7.webp)
![Main Product Image](https://assets.aleta.hr/415x415/95fe00cf-b219-4582-9996-5883594e3cf7.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400 - 16000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Type of electrical connection of main circuit
Screw connection
Overload release current setting
640 - 1600A
Rated voltage
690 - 690V
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device fixed built-in technique
Type of control element
Toggle
Number of poles
4
Position of connection for main current circuit
Front side
With integrated under voltage release
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
Yes
Degree of protection (IP)
IP40
Complete device with protection unit
Yes
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33485
![Main Product Image](https://assets.aleta.hr/300x300/58f93a4a-02a3-4e0c-9128-74293e8d56bf_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400 .. 16000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Type of electrical connection of main circuit
Screw connection
Overload release current setting
640 .. 1600A
Rated voltage
690 .. 690V
DIN rail (top hat rail) mounting optional
Device construction
Built-in device fixed built-in technique
Type of control element
Toggle
Number of poles
4
Position of connection for main current circuit
Front side
With integrated under voltage release
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
Degree of protection (IP)
IP40
Complete device with protection unit
Motor drive integrated
From same serie