- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Rated permanent current Iu
1000A
Overload release current setting
400 - 1000A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Type of electrical connection of main circuit
Screw connection
Adjustment range undelayed short-circuit release
1500 - 10000A
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Type of control element
Toggle
Complete device with protection unit
Yes
Position of connection for main current circuit
Front side
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release
No
DIN rail (top hat rail) mounting optional
No
Degree of protection (IP)
IP40
Integrated earth fault protection
No
Motor drive integrated
No
Motor drive optional
Yes
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33475
![Main Product Image](https://assets.aleta.hr/300x300/c0c96d42-e221-48d2-8209-0965bfeb0cbe_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Rated permanent current Iu
1000A
Overload release current setting
400 .. 1000A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Type of electrical connection of main circuit
Screw connection
Adjustment range undelayed short-circuit release
1500 .. 10000A
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Type of control element
Toggle
Complete device with protection unit
Position of connection for main current circuit
Front side
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release
DIN rail (top hat rail) mounting optional
Degree of protection (IP)
IP40
Integrated earth fault protection
Motor drive integrated
Motor drive optional
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Suitable for DIN rail (top hat rail) mounting