![Main Product Image](https://assets.aleta.hr/415x415/c8fd21e8-709f-4979-a718-bd31d653e9ee.webp)
![Main Product Image](https://assets.aleta.hr/415x415/c8fd21e8-709f-4979-a718-bd31d653e9ee.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Rated voltage
690 - 690V
Rated permanent current Iu
630A
Power loss
40W
Overload release current setting
252 - 630A
Device construction
Built-in device fixed built-in technique
Adjustment range undelayed short-circuit release
945 - 6300A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
No
With switched-off indicator
Yes
Number of poles
4
Number of auxiliary contacts as change-over contact
0
Type of control element
Toggle
Complete device with protection unit
Yes
Position of connection for main current circuit
Front side
With integrated under voltage release
No
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Degree of protection (IP)
IP40
Motor drive integrated
No
Motor drive optional
Yes
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Screw connection
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33463
![Main Product Image](https://assets.aleta.hr/300x300/2adde498-62ed-4b82-ab10-fa8daedd8b99_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Rated voltage
690 .. 690V
Rated permanent current Iu
630A
Power loss
40W
Overload release current setting
252 .. 630A
Device construction
Built-in device fixed built-in technique
Adjustment range undelayed short-circuit release
945 .. 6300A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
With switched-off indicator
Number of poles
4
Number of auxiliary contacts as change-over contact
0
Type of control element
Toggle
Complete device with protection unit
Position of connection for main current circuit
Front side
With integrated under voltage release
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Degree of protection (IP)
IP40
Motor drive integrated
Motor drive optional
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Screw connection
From same serie
We use cookies to enhance your experience.