![Main Product Image](https://assets.aleta.hr/415x415/ba877102-5639-49d2-ad6c-f3bd3a4a89e9.webp)
![Main Product Image](https://assets.aleta.hr/415x415/ba877102-5639-49d2-ad6c-f3bd3a4a89e9.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- - -A
Adjustment range undelayed short-circuit release
- - -A
Adjustment range short-term delayed short-circuit release
- - -A
Rated permanent current Iu
1250A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device slide-in technique (withdrawable)
Complete device with protection unit
No
With switched-off indicator
Yes
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
Yes
Power loss
252W
DIN rail (top hat rail) mounting optional
No
With integrated under voltage release
No
Integrated earth fault protection
No
Type of control element
Toggle
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Front side
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
No
Degree of protection (IP)
IP40
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33350
![Main Product Image](https://assets.aleta.hr/300x300/00a27693-69c4-4be4-8569-9e6590e5677a_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- .. -A
Adjustment range undelayed short-circuit release
- .. -A
Adjustment range short-term delayed short-circuit release
- .. -A
Rated permanent current Iu
1250A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device slide-in technique (withdrawable)
Complete device with protection unit
With switched-off indicator
Suitable for DIN rail (top hat rail) mounting
Motor drive optional
Power loss
252W
DIN rail (top hat rail) mounting optional
With integrated under voltage release
Integrated earth fault protection
Type of control element
Toggle
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Front side
Number of auxiliary contacts as change-over contact
0
Motor drive integrated
Degree of protection (IP)
IP40
Number of auxiliary contacts as normally open contact
0
Number of poles
3
From same serie