![Main Product Image](https://assets.aleta.hr/415x415/ac6301a5-c649-4556-90e3-6fc292d59c47.webp)
![Main Product Image](https://assets.aleta.hr/415x415/ac6301a5-c649-4556-90e3-6fc292d59c47.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- - -A
Adjustment range undelayed short-circuit release
- - -A
Adjustment range short-term delayed short-circuit release
- - -A
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Rated voltage
690 - 690V
Type of electrical connection of main circuit
Bolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
No
Rated permanent current Iu
800A
Motor drive integrated
Yes
With integrated under voltage release
No
Number of auxiliary contacts as change-over contact
0
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Front side
With switched-off indicator
Yes
Type of control element
Push button
Degree of protection (IP)
IP40
Motor drive optional
No
Complete device with protection unit
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33285
![Main Product Image](https://assets.aleta.hr/300x300/aa289ed4-26b3-44ba-a10f-749b598b5ff5_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- .. -A
Adjustment range undelayed short-circuit release
- .. -A
Adjustment range short-term delayed short-circuit release
- .. -A
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Rated voltage
690 .. 690V
Type of electrical connection of main circuit
Bolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
Rated permanent current Iu
800A
Motor drive integrated
With integrated under voltage release
Number of auxiliary contacts as change-over contact
0
Number of poles
4
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Front side
With switched-off indicator
Type of control element
Push button
Degree of protection (IP)
IP40
Motor drive optional
Complete device with protection unit
From same serie
We use cookies to enhance your experience.