![Main Product Image](https://assets.aleta.hr/415x415/d80ab967-1fe6-4de3-b24a-126a01dcb4df.webp)
![Main Product Image](https://assets.aleta.hr/415x415/d80ab967-1fe6-4de3-b24a-126a01dcb4df.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- - -A
Adjustment range undelayed short-circuit release
- - -A
Adjustment range short-term delayed short-circuit release
- - -A
Rated voltage
690 - 690V
Integrated earth fault protection
No
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
No
Power loss
66W
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
1000A
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
Yes
With integrated under voltage release
No
Type of control element
Toggle
Position of connection for main current circuit
Front side
Number of poles
3
Complete device with protection unit
No
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP40
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
33240
![Main Product Image](https://assets.aleta.hr/300x300/8421b0e7-49c7-451e-b3f1-c1afc584e7d9_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Overload release current setting
- .. -A
Adjustment range undelayed short-circuit release
- .. -A
Adjustment range short-term delayed short-circuit release
- .. -A
Rated voltage
690 .. 690V
Integrated earth fault protection
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
Power loss
66W
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
1000A
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
With integrated under voltage release
Type of control element
Toggle
Position of connection for main current circuit
Front side
Number of poles
3
Complete device with protection unit
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP40
From same serie
We use cookies to enhance your experience.