Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
100kA
Switching power at 400 V
-kW
Version as main switch
Yes
Version as emergency stop installation
Yes
Version as reversing switch
No
Version as maintenance-/service switch
Yes
Max. rated operation voltage Ue AC
690V
Version as safety switch
No
Rated permanent current Iu
1000A
Number of switches
1
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-23, 400 V
1000A
Rated permanent current at AC-21, 400 V
1000A
Motor drive optional
No
Device construction
Built-in device fixed built-in technique
Rated operation power at AC-23, 400 V
560kW
Voltage release optional
No
Number of poles
3
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
4
Suitable for front mounting 4-hole
Yes
Rated operating voltage
690 - 690V
Suitable for distribution board installation
Yes
Suitable for front mounting centre
Yes
Colour control element
Red
Type of control element
Long turning handle
Suitable for intermediate mounting
No
Type of electrical connection of main circuit
Screw connection
Interlockable
Yes
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP), front side
IP40
Suitable for floor mounting
Yes
Rated short-time withstand current lcw
50kA
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
31346
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
100kA
Switching power at 400 V
-kW
Version as main switch
Version as emergency stop installation
Version as reversing switch
Version as maintenance-/service switch
Max. rated operation voltage Ue AC
690V
Version as safety switch
Rated permanent current Iu
1000A
Number of switches
1
Number of auxiliary contacts as normally open contact
0
Rated permanent current at AC-23, 400 V
1000A
Rated permanent current at AC-21, 400 V
1000A
Motor drive optional
Device construction
Built-in device fixed built-in technique
Rated operation power at AC-23, 400 V
560kW
Voltage release optional
Number of poles
3
Motor drive integrated
Number of auxiliary contacts as change-over contact
4
Suitable for front mounting 4-hole
Rated operating voltage
690 .. 690V
Suitable for distribution board installation
Suitable for front mounting centre
Colour control element
Red
Type of control element
Long turning handle
Suitable for intermediate mounting
Type of electrical connection of main circuit
Screw connection
Interlockable
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP), front side
IP40
Suitable for floor mounting
Rated short-time withstand current lcw
50kA