Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
36kA
Rated permanent current at AC-21, 400 V
-A
Switching power at 400 V
-kW
Max. rated operation voltage Ue AC
690V
Rated permanent current Iu
250A
Version as main switch
Yes
Version as emergency stop installation
Yes
Version as safety switch
No
Version as reversing switch
No
Rated operation power at AC-23, 400 V
132kW
Number of switches
1
Number of poles
4
Rated operating voltage
690 - 690V
Rated short-time withstand current lcw
8.5kA
Suitable for front mounting centre
Yes
Suitable for floor mounting
Yes
Number of auxiliary contacts as normally closed contact
0
Suitable for distribution board installation
Yes
Number of auxiliary contacts as normally open contact
0
Voltage release optional
No
Suitable for front mounting 4-hole
Yes
Number of auxiliary contacts as change-over contact
2
Suitable for intermediate mounting
No
Type of electrical connection of main circuit
Screw connection
Motor drive optional
No
Motor drive integrated
No
Interlockable
Yes
Device construction
Built-in device fixed built-in technique
Rated permanent current at AC-23, 400 V
250A
Degree of protection (IP), front side
IP40
Type of control element
Long turning handle
Colour control element
Red
Version as maintenance-/service switch
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
31127
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
36kA
Rated permanent current at AC-21, 400 V
-A
Switching power at 400 V
-kW
Max. rated operation voltage Ue AC
690V
Rated permanent current Iu
250A
Version as main switch
Version as emergency stop installation
Version as safety switch
Version as reversing switch
Rated operation power at AC-23, 400 V
132kW
Number of switches
1
Number of poles
4
Rated operating voltage
690 .. 690V
Rated short-time withstand current lcw
8.5kA
Suitable for front mounting centre
Suitable for floor mounting
Number of auxiliary contacts as normally closed contact
0
Suitable for distribution board installation
Number of auxiliary contacts as normally open contact
0
Voltage release optional
Suitable for front mounting 4-hole
Number of auxiliary contacts as change-over contact
2
Suitable for intermediate mounting
Type of electrical connection of main circuit
Screw connection
Motor drive optional
Motor drive integrated
Interlockable
Device construction
Built-in device fixed built-in technique
Rated permanent current at AC-23, 400 V
250A
Degree of protection (IP), front side
IP40
Type of control element
Long turning handle
Colour control element
Red
Version as maintenance-/service switch