Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
150kA
Rated permanent current at AC-21, 400 V
-A
Switching power at 400 V
-kW
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as safety switch
No
Version as reversing switch
No
Number of switches
1
Rated operating voltage
690 - 690V
Rated permanent current at AC-23, 400 V
320A
Max. rated operation voltage Ue AC
690V
Rated operation power at AC-23, 400 V
160kW
Rated short-time withstand current lcw
20kA
Number of poles
3
Rated permanent current Iu
320A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Motor drive optional
No
Suitable for front mounting centre
Yes
Voltage release optional
No
Number of auxiliary contacts as change-over contact
4
Suitable for floor mounting
Yes
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
Yes
Suitable for distribution board installation
Yes
Interlockable
Yes
Version as emergency stop installation
No
Suitable for intermediate mounting
No
Colour control element
Black
Type of control element
Long turning handle
Degree of protection (IP), front side
IP40
Type of electrical connection of main circuit
Screw connection
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
31108
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
150kA
Rated permanent current at AC-21, 400 V
-A
Switching power at 400 V
-kW
Version as main switch
Version as maintenance-/service switch
Version as safety switch
Version as reversing switch
Number of switches
1
Rated operating voltage
690 .. 690V
Rated permanent current at AC-23, 400 V
320A
Max. rated operation voltage Ue AC
690V
Rated operation power at AC-23, 400 V
160kW
Rated short-time withstand current lcw
20kA
Number of poles
3
Rated permanent current Iu
320A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Motor drive optional
Suitable for front mounting centre
Voltage release optional
Number of auxiliary contacts as change-over contact
4
Suitable for floor mounting
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
Suitable for distribution board installation
Interlockable
Version as emergency stop installation
Suitable for intermediate mounting
Colour control element
Black
Type of control element
Long turning handle
Degree of protection (IP), front side
IP40
Type of electrical connection of main circuit
Screw connection