Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Switching power at 400 V
-kW
Rated permanent current at AC-21, 400 V
-A
Version as emergency stop installation
Yes
Version as maintenance-/service switch
Yes
Version as safety switch
No
Version as main switch
Yes
Version as reversing switch
No
Rated permanent current at AC-23, 400 V
72A
Rated permanent current Iu
80A
Number of switches
1
Rated short-time withstand current lcw
3kA
Rated operation power at AC-23, 400 V
37kW
Max. rated operation voltage Ue AC
500V
Conditioned rated short-circuit current Iq
36kA
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated operating voltage
690 - 690V
Number of poles
4
Number of auxiliary contacts as change-over contact
2
Suitable for floor mounting
Yes
Suitable for front mounting centre
Yes
Voltage release optional
No
Device construction
Built-in device fixed built-in technique
Suitable for distribution board installation
Yes
Motor drive integrated
No
Motor drive optional
No
Suitable for front mounting 4-hole
Yes
Colour control element
Red
Type of control element
Long turning handle
Suitable for intermediate mounting
No
Type of electrical connection of main circuit
Screw connection
Interlockable
Yes
Degree of protection (IP), front side
IP40
From same serie
28921

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- SCHNEIDER
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Switching power at 400 V
-kW
Rated permanent current at AC-21, 400 V
-A
Version as emergency stop installation
Version as maintenance-/service switch
Version as safety switch
Version as main switch
Version as reversing switch
Rated permanent current at AC-23, 400 V
72A
Rated permanent current Iu
80A
Number of switches
1
Rated short-time withstand current lcw
3kA
Rated operation power at AC-23, 400 V
37kW
Max. rated operation voltage Ue AC
500V
Conditioned rated short-circuit current Iq
36kA
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated operating voltage
690 .. 690V
Number of poles
4
Number of auxiliary contacts as change-over contact
2
Suitable for floor mounting
Suitable for front mounting centre
Voltage release optional
Device construction
Built-in device fixed built-in technique
Suitable for distribution board installation
Motor drive integrated
Motor drive optional
Suitable for front mounting 4-hole
Colour control element
Red
Type of control element
Long turning handle
Suitable for intermediate mounting
Type of electrical connection of main circuit
Screw connection
Interlockable
Degree of protection (IP), front side
IP40
From same serie