Aleta.hr
Main Product Image

18871

Code: 1690420

ManufacturerRAZNO
Catalog number18871
Type
EAN code3303430188711

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for flush-mounted installation

No

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

47mm

Rated voltage

230V

Number of protected poles

2

Release characteristic

MA

Rated current

12.5A

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Voltage type

AC/DC

Rated impulse withstand voltage Uimp

8kV

Flush-mounted installation

No

Pollution degree

3

Concurrently switching neutral conductor

Yes

Additional equipment possible

Yes

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Frequency

50 - 60Hz

Over voltage category

4

Connectable conductor cross section solid-core

1.5 - 50mm²

Degree of protection (IP)

IP20

Explosion-proof

No

Width in number of modular spacings

3

Ambient temperature during operating

-30 - 70°C

Connectable conductor cross section multi-wired

1 - 35mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

18871

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Suitable for flush-mounted installation

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

47mm

Rated voltage

230V

Number of protected poles

2

Release characteristic

MA

Rated current

12.5A

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Voltage type

AC/DC

Rated impulse withstand voltage Uimp

8kV

Flush-mounted installation

Pollution degree

3

Concurrently switching neutral conductor

Additional equipment possible

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Frequency

50 .. 60Hz

Over voltage category

4

Connectable conductor cross section solid-core

1.5 .. 50mm²

Degree of protection (IP)

IP20

Explosion-proof

Width in number of modular spacings

3

Ambient temperature during operating

-30 .. 70°C

Connectable conductor cross section multi-wired

1 .. 35mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.