Aleta.hr
Main Product Image

18804

Code: 1690359

ManufacturerRAZNO
Catalog number18804
Type
EAN code3303430188049

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

C

Number of protected poles

3

Built-in depth

47mm

Number of poles (total)

3

Voltage type

AC/DC

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated current

40A

Rated impulse withstand voltage Uimp

8kV

Rated voltage

415V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Flush-mounted installation

No

Frequency

50 - 60Hz

Width in number of modular spacings

4.5

Concurrently switching neutral conductor

No

Over voltage category

4

Pollution degree

3

Additional equipment possible

Yes

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 - 35mm²

Ambient temperature during operating

-30 - 70°C

Explosion-proof

No

Connectable conductor cross section solid-core

1.5 - 50mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

18804

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

C

Number of protected poles

3

Built-in depth

47mm

Number of poles (total)

3

Voltage type

AC/DC

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated current

40A

Rated impulse withstand voltage Uimp

8kV

Rated voltage

415V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Flush-mounted installation

Frequency

50 .. 60Hz

Width in number of modular spacings

4.5

Concurrently switching neutral conductor

Over voltage category

4

Pollution degree

3

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 35mm²

Ambient temperature during operating

-30 .. 70°C

Explosion-proof

Connectable conductor cross section solid-core

1.5 .. 50mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.