Aleta.hr
Main Product Image

18662

Code: 1690233

ManufacturerRAZNO
Catalog number18662
Type
EAN code3303430186625

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

47mm

Rated insulation voltage Ui

690V

Number of poles (total)

4

Number of protected poles

4

Rated current

125A

Rated impulse withstand voltage Uimp

8kV

Release characteristic

C

Voltage type

AC/DC

Flush-mounted installation

No

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Concurrently switching neutral conductor

Yes

Pollution degree

3

Over voltage category

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Additional equipment possible

Yes

Ambient temperature during operating

-30 - 70°C

Connectable conductor cross section multi-wired

10 - 50mm²

Width in number of modular spacings

6

Connectable conductor cross section solid-core

16 - 70mm²

Explosion-proof

No

Degree of protection (IP)

IP20

Rated voltage

400V

Frequency

50 - 60Hz


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

18662

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

47mm

Rated insulation voltage Ui

690V

Number of poles (total)

4

Number of protected poles

4

Rated current

125A

Rated impulse withstand voltage Uimp

8kV

Release characteristic

C

Voltage type

AC/DC

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Concurrently switching neutral conductor

Pollution degree

3

Over voltage category

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Additional equipment possible

Ambient temperature during operating

-30 .. 70°C

Connectable conductor cross section multi-wired

10 .. 50mm²

Width in number of modular spacings

6

Connectable conductor cross section solid-core

16 .. 70mm²

Explosion-proof

Degree of protection (IP)

IP20

Rated voltage

400V

Frequency

50 .. 60Hz