Aleta.hr
Main Product Image

18638

Code: 1690214

ManufacturerRAZNO
Catalog number18638
Type
EAN code3303430186380

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

3

Release characteristic

C

Rated voltage

400V

Voltage type

AC/DC

Rated impulse withstand voltage Uimp

8kV

Rated current

50A

Rated insulation voltage Ui

690V

Built-in depth

47mm

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Flush-mounted installation

No

Number of protected poles

3

Over voltage category

4

Frequency

50 - 60Hz

Connectable conductor cross section solid-core

1.5 - 50mm²

Additional equipment possible

Yes

Pollution degree

3

Explosion-proof

No

Ambient temperature during operating

-30 - 70°C

Width in number of modular spacings

4.5

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 - 35mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

18638

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • SCHNEIDER

Technical specifications

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

3

Release characteristic

C

Rated voltage

400V

Voltage type

AC/DC

Rated impulse withstand voltage Uimp

8kV

Rated current

50A

Rated insulation voltage Ui

690V

Built-in depth

47mm

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Flush-mounted installation

Number of protected poles

3

Over voltage category

4

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

1.5 .. 50mm²

Additional equipment possible

Pollution degree

3

Explosion-proof

Ambient temperature during operating

-30 .. 70°C

Width in number of modular spacings

4.5

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

1 .. 35mm²

From same serie