![Main Product Image](https://assets.aleta.hr/415x415/fc0b5b49-e691-4eb3-8f2d-62eef12bd023.webp)
![Main Product Image](https://assets.aleta.hr/415x415/fc0b5b49-e691-4eb3-8f2d-62eef12bd023.webp)
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- ABB
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
Number of conductors (without earthing)
2
System configuration DC
No
System configuration TT
Yes
System configuration TN-S
Yes
Nominal voltage AC
230V
System configuration TN-C-S
Yes
System configuration TN-C
No
System configuration other
No
Nominal discharge surge current (8/20)
20kA
Max. continuous voltage AC
275V
System configuration TN
Yes
System configuration IT
No
Short-circuit breaking capacity (Isccr)
100kA
Mounting method
DIN rail (top hat rail) 35 mm
Integrated backup fuse
Yes
With remote signalling contact
No
Voltage protection level N-PE
1.4kV
Voltage protection level
1.4kV
Signalling at the device
Optic
Category type 2
Yes
Degree of protection (IP)
IP20
Construction size
2 modular spacing
Voltage protection level L-N
1.4kV
Max. conductor cross section flexible (fine-strand)
16mm²
Max. discharge surge current (8/20)
80kA
Max. conductor cross section solid (solid, stranded)
25mm²
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
2CTB815704R1400 | OVR T2 1N 40-275s P QS
![Main Product Image](https://assets.aleta.hr/300x300/2a16b5b6-72bd-4268-bd67-3742cbab7981_optimized.webp)
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- ABB
Technical specifications
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
Number of conductors (without earthing)
2
System configuration DC
System configuration TT
System configuration TN-S
Nominal voltage AC
230V
System configuration TN-C-S
System configuration TN-C
System configuration other
Nominal discharge surge current (8/20)
20kA
Max. continuous voltage AC
275V
System configuration TN
System configuration IT
Short-circuit breaking capacity (Isccr)
100kA
Mounting method
DIN rail (top hat rail) 35 mm
Integrated backup fuse
With remote signalling contact
Voltage protection level N-PE
1.4kV
Voltage protection level
1.4kV
Signalling at the device
Optic
Category type 2
Degree of protection (IP)
IP20
Construction size
2 modular spacing
Voltage protection level L-N
1.4kV
Max. conductor cross section flexible (fine-strand)
16mm²
Max. discharge surge current (8/20)
80kA
Max. conductor cross section solid (solid, stranded)