Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- OBO
Technical specifications
System configuration DC
No
System configuration IT
No
System configuration TN-C
No
System configuration other
No
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
Voltage protection level L-PE
-kV
Voltage protection level N-PE
-kV
Voltage protection level (DC+ - DC-)
-kV
Voltage protection level (DC+/DC- - PE)
-kV
Max. overcurrent protection device, parallel connection (fuse)
-A
Max. overcurrent protection device, series connection (fuse)
-A
Specific energy (W/R)
-kJ/Ohm
Max. conductor cross section flexible (fine-strand)
35mm²
Remote signalling
No
Energy-coordinated protection effect with regard to the terminal equipment
No
Voltage switching spark gap technology
No
Overcurrent protected voltage tapping
No
System configuration TN
Yes
Integrated backup fuse
No
Degree of protection (IP)
IP20
System configuration TT
Yes
Nominal voltage AC
230V
Follow current extinguishing capability
0.1kA
Mounting method
DIN rail (top hat rail) 35 mm
Number of poles
2
Lightning impulse current (10/350 µs)
12.5kA
System configuration TN-C-S
Yes
Max. conductor cross section solid (solid, stranded)
35mm²
Voltage protection level L-N
1.3kV
Construction size
2 modular spacing
Max. continuous voltage AC
280V
Voltage protection level
1.3kV
System configuration TN-S
Yes
Signalling at the device
Optic
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
5093531 | V50-1+NPE+FS-280

Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- OBO
Technical specifications
System configuration DC
System configuration IT
System configuration TN-C
System configuration other
Max. continuous voltage DC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
Voltage protection level L-PE
-kV
Voltage protection level N-PE
-kV
Voltage protection level (DC+ - DC-)
-kV
Voltage protection level (DC+/DC- - PE)
-kV
Max. overcurrent protection device, parallel connection (fuse)
-A
Max. overcurrent protection device, series connection (fuse)
-A
Specific energy (W/R)
-kJ/Ohm
Max. conductor cross section flexible (fine-strand)
35mm²
Remote signalling
Energy-coordinated protection effect with regard to the terminal equipment
Voltage switching spark gap technology
Overcurrent protected voltage tapping
System configuration TN
Integrated backup fuse
Degree of protection (IP)
IP20
System configuration TT
Nominal voltage AC
230V
Follow current extinguishing capability
0.1kA
Mounting method
DIN rail (top hat rail) 35 mm
Number of poles
2
Lightning impulse current (10/350 µs)
12.5kA
System configuration TN-C-S
Max. conductor cross section solid (solid, stranded)
35mm²
Voltage protection level L-N
1.3kV
Construction size
2 modular spacing
Max. continuous voltage AC
280V
Voltage protection level
1.3kV
System configuration TN-S
Signalling at the device
Optic