5093452 | V50-1+NPE-150
Code: 1646121
Code: 1646121
Exhausting
No
System configuration DC
No
System configuration IT
No
System configuration TN
Yes
System configuration TN-C
No
System configuration TN-C-S
Yes
System configuration TN-S
Yes
System configuration TT
Yes
System configuration other
No
Number of poles
2
Lightning impulse current (10/350 µs)
12.5kA
Max. continuous voltage AC
150V
Max. continuous voltage DC
-V
Nominal voltage AC
120V
Nominal voltage DC
-V
Max. PV-voltage
-V
Voltage protection level
0.8kV
Voltage protection level L-N
0.8kV
Voltage protection level L-PE
-kV
Voltage protection level N-PE
-kV
Voltage protection level (DC+ - DC-)
-kV
Voltage protection level (DC+/DC- - PE)
-kV
Follow current extinguishing capability
0.1kA
Specific energy (W/R)
-kJ/Ohm
Max. overcurrent protection device, series connection (fuse)
-A
Max. overcurrent protection device, parallel connection (fuse)
-A
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
2 modular spacing
Max. conductor cross section solid (solid, stranded)
35mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Remote signalling
No
Signalling at the device
Optic
Integrated backup fuse
No
Energy-coordinated protection effect with regard to the terminal equipment
No
Voltage switching spark gap technology
No
Overcurrent protected voltage tapping
No
Degree of protection (IP)
IP20
Zagreb:
0 pcs
Zadar:
0 pcs
5093452 | V50-1+NPE-150
Exhausting
System configuration DC
System configuration IT
System configuration TN
System configuration TN-C
System configuration TN-C-S
System configuration TN-S
System configuration TT
System configuration other
Number of poles
2
Lightning impulse current (10/350 µs)
12.5kA
Max. continuous voltage AC
150V
Max. continuous voltage DC
-V
Nominal voltage AC
120V
Nominal voltage DC
-V
Max. PV-voltage
-V
Voltage protection level
0.8kV
Voltage protection level L-N
0.8kV
Voltage protection level L-PE
-kV
Voltage protection level N-PE
-kV
Voltage protection level (DC+ - DC-)
-kV
Voltage protection level (DC+/DC- - PE)
-kV
Follow current extinguishing capability
0.1kA
Specific energy (W/R)
-kJ/Ohm
Max. overcurrent protection device, series connection (fuse)
-A
Max. overcurrent protection device, parallel connection (fuse)
-A
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
2 modular spacing
Max. conductor cross section solid (solid, stranded)
35mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Remote signalling
Signalling at the device
Optic
Integrated backup fuse
Energy-coordinated protection effect with regard to the terminal equipment
Voltage switching spark gap technology
Overcurrent protected voltage tapping
Degree of protection (IP)
IP20