

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
No
System configuration TN
No
System configuration IT
Yes
System configuration other
No
System configuration TN-C-S
No
Number of conductors (without earthing)
2
System configuration TT
No
Nominal voltage DC
1170V
Nominal discharge surge current (8/20)
15kA
Max. continuous voltage DC
1170V
System configuration TN-C
No
Voltage protection level N-PE
0kV
Voltage protection level L-N
0kV
Voltage protection level
3.5kV
Integrated short-circuit protection
No
System configuration TN-S
No
Max. continuous voltage AC
0V
Integrated short-circuit protection selective to fuse gG
0A
Nominal voltage AC
0V
Max. discharge surge current (8/20)
40kA
Integrated backup fuse
No
Construction size
3 modular spacing
Short-circuit breaking capacity (Isccr)
0kA
Leakage-current free
No
Max. conductor cross section flexible (fine-strand)
0mm²
With remote signalling contact
Yes
Degree of protection (IP)
IP20
Max. conductor cross section solid (solid, stranded)
0mm²
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. overcurrent protection device, series connection (fuse)
0A
Mounting method
DIN rail (top hat rail) 35 mm
Max. PV-voltage
1170V
Category type 2
Yes
Signalling at the device
Optic
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPPVT12-10-2+PE-AX

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
System configuration TN
System configuration IT
System configuration other
System configuration TN-C-S
Number of conductors (without earthing)
2
System configuration TT
Nominal voltage DC
1170V
Nominal discharge surge current (8/20)
15kA
Max. continuous voltage DC
1170V
System configuration TN-C
Voltage protection level N-PE
0kV
Voltage protection level L-N
0kV
Voltage protection level
3.5kV
Integrated short-circuit protection
System configuration TN-S
Max. continuous voltage AC
0V
Integrated short-circuit protection selective to fuse gG
0A
Nominal voltage AC
0V
Max. discharge surge current (8/20)
40kA
Integrated backup fuse
Construction size
3 modular spacing
Short-circuit breaking capacity (Isccr)
0kA
Leakage-current free
Max. conductor cross section flexible (fine-strand)
0mm²
With remote signalling contact
Degree of protection (IP)
IP20
Max. conductor cross section solid (solid, stranded)
0mm²
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. overcurrent protection device, series connection (fuse)
0A
Mounting method
DIN rail (top hat rail) 35 mm
Max. PV-voltage
1170V
Category type 2
Signalling at the device
Optic
From same serie
We use cookies to enhance your experience.