Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
No
System configuration IT
Yes
System configuration TN-S
No
System configuration TN
No
System configuration TN-C
No
System configuration TT
No
Number of conductors (without earthing)
0
Nominal discharge surge current (8/20)
15kA
Nominal voltage AC
0V
Nominal voltage DC
487.5V
Max. discharge surge current (8/20)
0kA
System configuration other
No
System configuration TN-C-S
No
Max. continuous voltage AC
0V
Max. continuous voltage DC
585V
Max. PV-voltage
585V
Voltage protection level
1.8kV
Voltage protection level L-N
0kV
Voltage protection level N-PE
0kV
Integrated short-circuit protection
No
Max. overcurrent protection device, series connection (fuse)
0A
Max. overcurrent protection device, parallel connection (fuse)
0A
Short-circuit breaking capacity (Isccr)
0kA
Integrated short-circuit protection selective to fuse gG
0A
Integrated backup fuse
No
Construction size
1 modular spacing
Max. conductor cross section flexible (fine-strand)
0mm²
Max. conductor cross section solid (solid, stranded)
0mm²
Category type 2
Yes
Mounting method
On basic element
Signalling at the device
Optic
Degree of protection (IP)
IP20
Leakage-current free
No
With remote signalling contact
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPPVT12-10

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
System configuration IT
System configuration TN-S
System configuration TN
System configuration TN-C
System configuration TT
Number of conductors (without earthing)
0
Nominal discharge surge current (8/20)
15kA
Nominal voltage AC
0V
Nominal voltage DC
487.5V
Max. discharge surge current (8/20)
0kA
System configuration other
System configuration TN-C-S
Max. continuous voltage AC
0V
Max. continuous voltage DC
585V
Max. PV-voltage
585V
Voltage protection level
1.8kV
Voltage protection level L-N
0kV
Voltage protection level N-PE
0kV
Integrated short-circuit protection
Max. overcurrent protection device, series connection (fuse)
0A
Max. overcurrent protection device, parallel connection (fuse)
0A
Short-circuit breaking capacity (Isccr)
0kA
Integrated short-circuit protection selective to fuse gG
0A
Integrated backup fuse
Construction size
1 modular spacing
Max. conductor cross section flexible (fine-strand)
0mm²
Max. conductor cross section solid (solid, stranded)
0mm²
Category type 2
Mounting method
On basic element
Signalling at the device
Optic
Degree of protection (IP)
IP20