Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TT
No
System configuration DC
No
Nominal voltage DC
600V
Number of conductors (without earthing)
2
System configuration TN-C-S
No
Voltage protection level
2.6kV
System configuration TN-S
No
Max. continuous voltage DC
720V
Voltage protection level N-PE
0kV
Max. overcurrent protection device, series connection (fuse)
0A
System configuration IT
Yes
Integrated short-circuit protection selective to fuse gG
0A
Max. continuous voltage AC
0V
Max. overcurrent protection device, parallel connection (fuse)
0A
System configuration TN
No
Construction size
3 modular spacing
Nominal discharge surge current (8/20)
15kA
Max. conductor cross section flexible (fine-strand)
0mm²
Mounting method
DIN rail (top hat rail) 35 mm
Max. PV-voltage
720V
Leakage-current free
No
Signalling at the device
Optic
Category type 2
Yes
Integrated short-circuit protection
No
System configuration TN-C
No
Voltage protection level L-N
0kV
Short-circuit breaking capacity (Isccr)
0kA
Max. discharge surge current (8/20)
40kA
Max. conductor cross section solid (solid, stranded)
0mm²
Degree of protection (IP)
IP20
With remote signalling contact
Yes
Integrated backup fuse
No
Nominal voltage AC
0V
System configuration other
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPPVT12-06-2+PE-AX

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TT
System configuration DC
Nominal voltage DC
600V
Number of conductors (without earthing)
2
System configuration TN-C-S
Voltage protection level
2.6kV
System configuration TN-S
Max. continuous voltage DC
720V
Voltage protection level N-PE
0kV
Max. overcurrent protection device, series connection (fuse)
0A
System configuration IT
Integrated short-circuit protection selective to fuse gG
0A
Max. continuous voltage AC
0V
Max. overcurrent protection device, parallel connection (fuse)
0A
System configuration TN
Construction size
3 modular spacing
Nominal discharge surge current (8/20)
15kA
Max. conductor cross section flexible (fine-strand)
0mm²
Mounting method
DIN rail (top hat rail) 35 mm
Max. PV-voltage
720V
Leakage-current free
Signalling at the device
Optic
Category type 2
Integrated short-circuit protection
System configuration TN-C
Voltage protection level L-N
0kV
Short-circuit breaking capacity (Isccr)
0kA
Max. discharge surge current (8/20)
40kA
Max. conductor cross section solid (solid, stranded)
0mm²
Degree of protection (IP)
IP20
With remote signalling contact
Integrated backup fuse
Nominal voltage AC
0V
System configuration other
From same serie
We use cookies to enhance your experience.