Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-S
No
Nominal discharge surge current (8/20)
15kA
System configuration TN-C-S
No
System configuration other
No
System configuration TN
No
Number of conductors (without earthing)
0
System configuration TT
No
Max. discharge surge current (8/20)
0kA
System configuration IT
Yes
Nominal voltage DC
300V
Max. PV-voltage
360V
System configuration DC
No
Voltage protection level
1.7kV
System configuration TN-C
No
Max. continuous voltage AC
0V
Nominal voltage AC
0V
Voltage protection level N-PE
0kV
Max. continuous voltage DC
360V
Voltage protection level L-N
0kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. overcurrent protection device, series connection (fuse)
0A
Short-circuit breaking capacity (Isccr)
0kA
Integrated short-circuit protection
No
Integrated short-circuit protection selective to fuse gG
0A
Mounting method
On basic element
Integrated backup fuse
No
Max. conductor cross section flexible (fine-strand)
0mm²
Leakage-current free
No
With remote signalling contact
No
Construction size
1 modular spacing
Max. conductor cross section solid (solid, stranded)
0mm²
Signalling at the device
Optic
Category type 2
Yes
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPPVT12-06

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-S
Nominal discharge surge current (8/20)
15kA
System configuration TN-C-S
System configuration other
System configuration TN
Number of conductors (without earthing)
0
System configuration TT
Max. discharge surge current (8/20)
0kA
System configuration IT
Nominal voltage DC
300V
Max. PV-voltage
360V
System configuration DC
Voltage protection level
1.7kV
System configuration TN-C
Max. continuous voltage AC
0V
Nominal voltage AC
0V
Voltage protection level N-PE
0kV
Max. continuous voltage DC
360V
Voltage protection level L-N
0kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. overcurrent protection device, series connection (fuse)
0A
Short-circuit breaking capacity (Isccr)
0kA
Integrated short-circuit protection
Integrated short-circuit protection selective to fuse gG
0A
Mounting method
On basic element
Integrated backup fuse
Max. conductor cross section flexible (fine-strand)
0mm²
Leakage-current free
With remote signalling contact
Construction size
1 modular spacing
Max. conductor cross section solid (solid, stranded)
0mm²
Signalling at the device
Optic
Category type 2
Degree of protection (IP)
IP20
From same serie