Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Yes
Version as maintenance-/service switch
Yes
Version as safety switch
No
Version as reversing switch
No
Number of switches
1
Version as emergency stop installation
No
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
25A
Rated permanent current at AC-23, 400 V
25A
Rated operation power at AC-3, 400 V
7.5kW
Rated permanent current Iu
25A
Rated operation power at AC-23, 400 V
13kW
Conditioned rated short-circuit current Iq
50kA
Switching power at 400 V
13kW
Rated short-time withstand current lcw
0.64kA
Rated operating voltage
690 - 690V
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Motor drive optional
No
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
0
Voltage release optional
No
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
No
Suitable for distribution board installation
No
Suitable for front mounting centre
No
Suitable for floor mounting
Yes
Suitable for intermediate mounting
Yes
With pre-assembled cabling
No
Type of electrical connection of main circuit
Screw connection
Interlockable
Yes
Type of control element
Door coupling rotary drive
Colour control element
Black
Degree of protection (NEMA)
12
Degree of protection (IP), front side
IP65
Width
72mm
Depth
340mm
Height
70mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
P1-25/M4/SVB-SW

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as main switch
Version as maintenance-/service switch
Version as safety switch
Version as reversing switch
Number of switches
1
Version as emergency stop installation
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
25A
Rated permanent current at AC-23, 400 V
25A
Rated operation power at AC-3, 400 V
7.5kW
Rated permanent current Iu
25A
Rated operation power at AC-23, 400 V
13kW
Conditioned rated short-circuit current Iq
50kA
Switching power at 400 V
13kW
Rated short-time withstand current lcw
0.64kA
Rated operating voltage
690 .. 690V
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Motor drive optional
Motor drive integrated
Number of auxiliary contacts as change-over contact
0
Voltage release optional
Device construction
Built-in device fixed built-in technique
Suitable for front mounting 4-hole
Suitable for distribution board installation
Suitable for front mounting centre
Suitable for floor mounting
Suitable for intermediate mounting
With pre-assembled cabling
Type of electrical connection of main circuit
Screw connection
Interlockable
Type of control element
Door coupling rotary drive
Colour control element
Black
Degree of protection (NEMA)
12
Degree of protection (IP), front side
IP65
Width
72mm
Depth
340mm
Height
70mm
From same serie
We use cookies to enhance your experience.